Read the docs
TI-2020-09696 Aliases CVE-2020-12037GHSA-crq7-9m4m-xx27

Cleartext transmission of sensitive information in Baxter PrismaFlex and PrisMax

Priority LOW 33CWE-259Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass, Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-259 and CWE-319.

Summary

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.

Why it matters now

EPSS 0.00483 41st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Baxter PrismaFlex and PrisMaxPrismaFlex all versions, PrisMax all versions prior to 3.x—No fix listedCNA
  • Baxter PrismaFlex and PrisMax Vendor— Affected PrismaFlex all versions, PrisMax all versions prior to 3.x Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:baxter:prismaflex_firmware:*:*:*:*:*:*:*:*all versionsVulnerableBaxter
cpe:2.3:h:baxter:prismaflex:-:*:*:*:*:*:*:*not specified by NVDRunning onBaxter
cpe:2.3:o:baxter:prismax_firmware:*:*:*:*:*:*:*:*before 3.0VulnerableBaxter
cpe:2.3:h:baxter:prismax:-:*:*:*:*:*:*:*not specified by NVDRunning onBaxter
  • cpe:2.3:o:baxter:prismaflex_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Baxter
  • cpe:2.3:h:baxter:prismaflex:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Baxter
  • cpe:2.3:o:baxter:prismax_firmware:*:*:*:*:*:*:*:* Versions before 3.0 Vulnerable ·Baxter
  • cpe:2.3:h:baxter:prismax:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Baxter

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-12037
  2. 2026-10-03 Alias added: GHSA-crq7-9m4m-xx27

References

  • TI-2020-09695 Cleartext transmission of sensitive information in Baxter PrismaFlex and PrisMax CVSS 3.1HIGH 7.5
  • TI-2020-09694 Improper authentication in Baxter PrismaFlex and PrisMax CVSS 3.1MEDIUM 4.9

Sources