Path traversal in Secomea GateManager
Key facts
- Attack vector
- Network
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · Low
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA.
Summary
A directory traversal vulnerability exists in the file upload function of the GateManager that allows an authenticated attacker with administrative permissions to read and write arbitrary files in the Linux file system. This issue affects: GateManager all versions prior to 9.2c.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Secomea | GateManager | All to before 9.2c | 9.2c | Patch available | CNA |
- GateManager VendorSecomea Affected All to before 9.2c Fixed in 9.2c Patch available CNA
CPE configurations NVD · 8
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:* | before 9.2c | Vulnerable | Secomea |
| cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Secomea |
| cpe:2.3:o:secomea:gatemanager_4250_firmware:*:*:*:*:*:*:*:* | before 9.0i | Vulnerable | Secomea |
| cpe:2.3:h:secomea:gatemanager_4250:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Secomea |
| cpe:2.3:o:secomea:gatemanager_4260_firmware:*:*:*:*:*:*:*:* | before 9.0i | Vulnerable | Secomea |
| cpe:2.3:h:secomea:gatemanager_4260:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Secomea |
| cpe:2.3:o:secomea:gatemanager_9250_firmware:*:*:*:*:*:*:*:* | before 9.0i | Vulnerable | Secomea |
| cpe:2.3:h:secomea:gatemanager_9250:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Secomea |
- cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:* Versions before 9.2c Vulnerable ·Secomea
- cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Secomea
- cpe:2.3:o:secomea:gatemanager_4250_firmware:*:*:*:*:*:*:*:* Versions before 9.0i Vulnerable ·Secomea
- cpe:2.3:h:secomea:gatemanager_4250:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Secomea
- cpe:2.3:o:secomea:gatemanager_4260_firmware:*:*:*:*:*:*:*:* Versions before 9.0i Vulnerable ·Secomea
- cpe:2.3:h:secomea:gatemanager_4260:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Secomea
- cpe:2.3:o:secomea:gatemanager_9250_firmware:*:*:*:*:*:*:*:* Versions before 9.0i Vulnerable ·Secomea
- cpe:2.3:h:secomea:gatemanager_9250:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Secomea
Remediation
- Fix · CNA GateManager (Secomea) Fixed in 9.2c
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Secomea GateManager 9.2c
2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW
Other records, highest priority first
- TI-2020-17537 Insecure Direct Object Reference in GateManager WebUI can cause privilege escalationPriority LOW 37
Timeline
- 2026-10-02 Threatist record created from CVE-2020-29026
- 2026-10-03 Alias added: GHSA-2m67-gph7-q4xp
References
More Secomea Gatemanager 4250 Firmware vulnerabilities
- TI-2022-09350 Unload handlers may unintentionally defeat CSRF guards CVSS 3.1HIGH 8.8
- TI-2020-17537 Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation CVSS 3.1HIGH 8.1
- TI-2021-11990 Clients may connect to a GateManager with TLS 1.0 CVSS 3.1HIGH 8.1
- TI-2022-09359 GTA URLs issued by LMM WEB API may leak information CVSS 3.1HIGH 7.5
- TI-2022-09353 Reflected XSS issues in GateManager CVSS 3.1MEDIUM 6.1
- TI-2020-17528 Host Header Injection allowing web cache poisoning attacks CVSS 3.1MEDIUM 5.3
Sources
- CVE-2020-29026 · CVE Program
- CVE-2020-29026 · NVD
- FIRST EPSS
- GHSA-2m67-gph7-q4xp · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences