Read the docs
TI-2021-05624 Aliases CVE-2021-22743GHSA-48h6-xg8f-qv46

Improper check for unusual conditions in Triconex TCM 4351B installed on Tricon V11.3.x…

Priority LOW 18CWE-754Published · Updated

Key facts

Attack vector
Physical
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.

Why it matters now

EPSS 0.00224 13th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Triconex TCM 4351B installed on Tricon V11.3.x systems.Triconex TCM 4351B installed on Tricon V11.3.x systems—No fix listedCNA
  • Triconex TCM 4351B installed on Tricon V11.3.x systems. Vendor— Affected Triconex TCM 4351B installed on Tricon V11.3.x systems Fixed in — No fix listed CNA

CPE configurations NVD · 5

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:triconex_model_3009_mp_firmware:*:*:*:*:*:*:*:*11.3.0 to before 11.8.0VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:triconex_model_3009_mp:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:tcm_4351b_firmware:*:*:*:*:*:*:*:*11.3.0 to before 11.5.1VulnerableSchneider Electric
cpe:2.3:o:schneider-electric:tcm_4351b_firmware:11.7.0:*:*:*:*:*:*:*11.7.0VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:tcm_4351b:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:triconex_model_3009_mp_firmware:*:*:*:*:*:*:*:* Versions 11.3.0 to before 11.8.0 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:triconex_model_3009_mp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:tcm_4351b_firmware:*:*:*:*:*:*:*:* Versions 11.3.0 to before 11.5.1 Vulnerable ·Schneider Electric
  • cpe:2.3:o:schneider-electric:tcm_4351b_firmware:11.7.0:*:*:*:*:*:*:* Versions 11.7.0 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:tcm_4351b:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-22743
  2. 2026-10-03 Alias added: GHSA-48h6-xg8f-qv46

References

  • TI-2021-05628 Improper check for unusual conditions in Triconex Model 3009 MP installed on Tricon… CVSS 3.1LOW 3.9
  • TI-2021-05627 Improper check for unusual conditions in Triconex Model 3009 MP installed on Tricon… CVSS 3.1LOW 3.9
  • TI-2021-05626 Improper check for unusual conditions in Triconex Model 3009 MP installed on Tricon… CVSS 3.1LOW 3.9
  • TI-2021-05625 Improper check for unusual conditions in Triconex Model 3009 MP installed on Tricon… CVSS 3.1LOW 3.9
  • TI-2021-05623 Improper check for unusual conditions in Triconex Model 3009 MP installed on Tricon… CVSS 3.1LOW 3.9

Sources