A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-79.
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 57
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* | up to 6.9.8 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_3500:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:network_management_card_2:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:single-phase_symmetra:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:smart-ups:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* | up to 6.9.6 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ap9922_battery_management_system:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:apc_rack_power_distribution_units:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_g7x:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_g9kchu:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
- cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* Versions up to 6.9.8 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_3500:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:network_management_card_2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:single-phase_symmetra:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:smart-ups:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* Versions up to 6.9.6 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ap9922_battery_management_system:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:apc_rack_power_distribution_units:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_g7x:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_g9kchu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Show 47 more CPE
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:h:schneider-electric:galaxy_gcxsa:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_gfc:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_gvmsa:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_gvmts:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_gvxts:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:galaxy_rpp_grppip2x84:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:gutor_gvx:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:gutor_sxw:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:netbotz_nbrk0250:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd40e5ek20-m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd40f6fk1-m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd40g6fk1-m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd40h5ek20-m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd40l6fk1-m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd60f6fk1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd60g6fk1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pd60l6fk1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpb150g6f:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm138h-5u:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm138h-r:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm144f:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm150g6f:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm150l6f:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm175g6h:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm277h:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm288g6h:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdpm72f-5u:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdrppnx10:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pdrppnx10m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm400-ala:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm400-alax:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm400-cub:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm500-ala:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm500-alax:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:pmm500-cub:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:rack_automatic_transfer_switches:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_100:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_160:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_20:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_250:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_40:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_48:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_500:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:symmetra_px_96:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* | up to 1.4.2.1 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:network_management_card_3:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* | up to 1.4.0 | Vulnerable | Schneider Electric |
- cpe:2.3:h:schneider-electric:galaxy_gcxsa:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_gfc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_gvmsa:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_gvmts:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_gvxts:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:galaxy_rpp_grppip2x84:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:gutor_gvx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:gutor_sxw:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:netbotz_nbrk0250:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd40e5ek20-m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd40f6fk1-m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd40g6fk1-m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd40h5ek20-m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd40l6fk1-m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd60f6fk1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd60g6fk1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pd60l6fk1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpb150g6f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm138h-5u:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm138h-r:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm144f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm150g6f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm150l6f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm175g6h:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm277h:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm288g6h:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdpm72f-5u:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdrppnx10:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pdrppnx10m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm400-ala:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm400-alax:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm400-cub:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm500-ala:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm500-alax:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:pmm500-cub:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:rack_automatic_transfer_switches:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_100:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_160:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_20:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_250:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_40:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_48:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_500:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:symmetra_px_96:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* Versions up to 1.4.2.1 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:network_management_card_3:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* Versions up to 1.4.0 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2021-22810
- 2026-10-03 Alias added: GHSA-qpf2-w9g6-82x6
References
More Schneider Electric Network Management Card 2 Firmware vulnerabilities
- TI-2021-05694 A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site… CVSS 3.1MEDIUM 6.1
- TI-2021-05693 A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site… CVSS 3.1MEDIUM 6.1
- TI-2021-05692 A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site… CVSS 3.1MEDIUM 6.1
- TI-2021-05691 A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site… CVSS 3.1MEDIUM 6.1
- TI-2021-05695 A CWE-200: Information Exposure vulnerability exists which could cause the… CVSS 3.1MEDIUM 5.3
Sources
- CVE-2021-22810 · CVE Program
- CVE-2021-22810 · NVD
- FIRST EPSS
- GHSA-qpf2-w9g6-82x6 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences