Read the docs
TI-2021-05700 Aliases CVE-2021-22820GHSA-2c5p-55qj-5p58

A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an…

Priority MEDIUM 44CWE-613Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-613.

Summary

A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Why it matters now

EPSS 0.01084 65th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 12

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:evlink_parking_evp2pe_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_parking_evp2pe:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:evlink_parking_evp2pe_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_parking_evp2pe:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Show 2 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*before 3.4.0.2VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:* Versions before 3.4.0.2 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-22820
  2. 2026-10-03 Alias added: GHSA-2c5p-55qj-5p58

References

  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2021-05610 A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 /… CVSS 3.1CRITICAL 9.8
  • TI-2021-05611 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2021-05608 A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4… CVSS 3.1CRITICAL 9.8
  • TI-2021-05701 A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the… CVSS 3.1HIGH 8.6
  • TI-2021-05607 Server-side request forgery in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1HIGH 8.1
See all 17 →