TI-2021-06206 Aliases CVE-2021-23842GHSA-j6hr-vmm6-m6c2

Use of Hard-coded Cryptographic Key

Priority LOW 30CWE-321Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · None
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-321.

Summary

Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.

Why it matters now

EPSS 0.00144 3rd percentileScored 2026-11-07
Fix Fixed AMS (Bosch): 4.0BIS (Bosch): 4.9.1

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
BoschAMSbefore 4.04.0Patch availableCNA
BoschAPEup to 3.8.x—No fix listedCNA
BoschBISbefore 4.9.14.9.1Patch availableCNA
BoschAMC2all—No fix listedCNA
  • AMS VendorBosch Affected before 4.0 Fixed in 4.0 Patch available CNA
  • APE VendorBosch Affected up to 3.8.x Fixed in — No fix listed CNA
  • BIS VendorBosch Affected before 4.9.1 Fixed in 4.9.1 Patch available CNA
  • AMC2 VendorBosch Affected all Fixed in — No fix listed CNA

CPE configurations NVD · 5

CPEVersionsRoleVendor
cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableBosch
cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:*3.0VulnerableBosch
cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*up to 3.8.0VulnerableBosch
cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*before 4.9.1VulnerableBosch
  • cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Bosch
  • cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:* Versions 3.0 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:* Versions up to 3.8.0 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:* Versions before 4.9.1 Vulnerable ·Bosch

Remediation

  • Fix · CNA AMS (Bosch) Fixed in 4.0
  • Fix · CNA BIS (Bosch) Fixed in 4.9.1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Bosch AMS, BIS 4.0, 4.9.1

    2 records Highest priority Priority LOW 2 LOW

    Other records, highest priority first

    • TI-2021-06207 Lack of authentication mechanisms on the devicePriority LOW 38

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-23842
  2. 2026-10-03 Alias added: GHSA-j6hr-vmm6-m6c2

References

  • TI-2021-06207 Lack of authentication mechanisms on the device CVSS 3.1HIGH 8.8

Sources