Infinite loop in Siemens Capital Embedded AR Classic 431-422
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Denial of service
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-835.
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Capital Embedded AR Classic 431-422 | all versions | — | No fix listed | CNA |
| Siemens | Capital Embedded AR Classic R20-11 | before V2303 | V2303 | Patch available | CNA |
| Siemens | Nucleus NET | All versions | — | No fix listed | CNA |
| Siemens | Nucleus ReadyStart V3 | before V2017.02.4 | V2017.02.4 | Patch available | CNA |
| Siemens | Nucleus ReadyStart V4 | before V4.1.0 | V4.1.0 | Patch available | CNA |
| Siemens | Nucleus Source Code | all versions | — | No fix listed | CNA |
- Capital Embedded AR Classic 431-422 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- Capital Embedded AR Classic R20-11 VendorSiemens Affected before V2303 Fixed in V2303 Patch available CNA
- Nucleus NET VendorSiemens Affected All versions Fixed in — No fix listed CNA
- Nucleus ReadyStart V3 VendorSiemens Affected before V2017.02.4 Fixed in V2017.02.4 Patch available CNA
- Nucleus ReadyStart V4 VendorSiemens Affected before V4.1.0 Fixed in V4.1.0 Patch available CNA
- Nucleus Source Code VendorSiemens Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 5
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:* | not specified by NVD | Vulnerable | Siemens |
| cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:* | before 4.1.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:* | not specified by NVD | Vulnerable | Siemens |
| cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:* | before 2017.02.4 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
- cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:* Versions before 4.1.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
- cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:* Versions before 2017.02.4 Vulnerable ·Siemens
Remediation
- Fix · CNA Capital Embedded AR Classic R20-11 (Siemens) Fixed in V2303
- Fix · CNA Nucleus ReadyStart V3 (Siemens) Fixed in V2017.02.4
- Fix · CNA Nucleus ReadyStart V4 (Siemens) Fixed in V4.1.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Capital Embedded AR Classic R20-11, Nucleus ReadyStart V3, Nucleus ReadyStart V4 V2017.02.4, V2303, V4.1.0
2 records Highest priority Priority MEDIUM 2 MEDIUM
Other records, highest priority first
- TI-2021-07796 Infinite loop in Siemens Capital Embedded AR Classic 431-422Priority MEDIUM 41
Timeline
- 2026-10-02 Threatist record created from CVE-2021-25663
- 2026-10-03 Alias added: GHSA-m3qf-xv59-6w6h
References
More Siemens Capital Vstar vulnerabilities
- TI-2021-11873 A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE… CVSS 3.1CRITICAL 9.8
- TI-2021-11879 A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All… CVSS 3.1CRITICAL 9.1
- TI-2021-11878 Integer underflow in Siemens Capital Embedded AR Classic 431-422 CVSS 3.1CRITICAL 9.1
- TI-2021-11490 A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All… CVSS 3.1CRITICAL 9.1
- TI-2021-11489 A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All… CVSS 3.1CRITICAL 9.1
- TI-2021-07796 Infinite loop in Siemens Capital Embedded AR Classic 431-422 CVSS 4.0HIGH 8.7
Sources
- CVE-2021-25663 · CVE Program
- CVE-2021-25663 · NVD
- FIRST EPSS
- GHSA-m3qf-xv59-6w6h · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences