Read the docs
TI-2021-08959 Aliases CVE-2021-27473GHSA-jcq6-j25v-gr6g

Rockwell Automation Connected Components Workbench Improper Input Validation

Priority LOW 37CWE-22Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file during extraction. This type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00783 56th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
RockwellConnected Components Workbenchup to v12.00.00—No fix listedCNA
  • Connected Components Workbench VendorRockwell Affected up to v12.00.00 Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:rockwellautomation:connected_components_workbench:*:*:*:*:*:*:*:*up to 12.00.00VulnerableRockwell
  • cpe:2.3:a:rockwellautomation:connected_components_workbench:*:*:*:*:*:*:*:* Versions up to 12.00.00 Vulnerable ·Rockwell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-27473
  2. 2026-10-03 Alias added: GHSA-jcq6-j25v-gr6g

References

  • TI-2014-04423 Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote… CVSS 2.0HIGH 7.5
  • TI-2021-08961 Rockwell Automation Connected Components Workbench Deserialization of Untrusted Data CVSS 3.1HIGH 8.6
  • TI-2021-08957 Rockwell Automation Connected Components Workbench Path Traversal CVSS 3.1HIGH 8.6
  • TI-2017-03292 Uncontrolled search path in Rockwell Automation Connected Components Workbench CVSS 3.0HIGH 7.0
  • TI-2022-00916 ICSA-22-088-01 Rockwell Automation ISaGRAF CVSS 3.1MEDIUM 5.5

Sources