Read the docs
TI-2021-11772 Aliases CVE-2021-31755GHSA-539c-2w6v-9rwx

An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN.

Priority CRITICAL 100Exploited in the wildCWE-787Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.

Summary

An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request.

Why it matters now

Exploitation Active In CISA KEV since 2021-11-03CISA due date 2021-11-17
EPSS 0.86511 99th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Active
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*up to 02.03.01.104_cnVulnerableTenda
cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:* Versions up to 02.03.01.104_cn Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2021-11-03 Added to CISA KEV
  2. 2026-10-02 Threatist record created from CVE-2021-31755
  3. 2026-10-03 Alias added: GHSA-539c-2w6v-9rwx

References

  • TI-2021-11775 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. CVSS 3.1CRITICAL 9.8
  • TI-2021-11774 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. CVSS 3.1CRITICAL 9.8
  • TI-2021-11773 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. CVSS 3.1CRITICAL 9.8
  • TI-2021-21157 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer… CVSS 3.1CRITICAL 9.8
  • TI-2021-21141 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer… CVSS 3.1CRITICAL 9.8
  • TI-2021-21140 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer… CVSS 3.1CRITICAL 9.8
See all 8 →

Sources