A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Denial of service
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-120 and the CVSS impact.
Summary
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and takes extensive time for the GUI to connect to the TCP socket, allowing the connection to be hijacked by an external attacker.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:swisslog-healthcare:hmi-3_control_panel_firmware:*:*:*:*:*:*:*:* | before 7.2.5.7 | Vulnerable | Swisslog-healthcare |
| cpe:2.3:h:swisslog-healthcare:hmi-3_control_panel:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Swisslog-healthcare |
- cpe:2.3:o:swisslog-healthcare:hmi-3_control_panel_firmware:*:*:*:*:*:*:*:* Versions before 7.2.5.7 Vulnerable ·Swisslog-healthcare
- cpe:2.3:h:swisslog-healthcare:hmi-3_control_panel:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Swisslog-healthcare
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2021-37166
- 2026-10-03 Alias added: GHSA-4wc5-93xp-9wmv
References
More Swisslog-healthcare Hmi-3 Control Panel Firmware vulnerabilities
- TI-2021-15226 A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare… CVSS 3.1CRITICAL 9.8
- TI-2021-15231 A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus… CVSS 3.1CRITICAL 9.8
- TI-2021-15230 A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus… CVSS 3.1CRITICAL 9.8
- TI-2021-15228 A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus… CVSS 3.1CRITICAL 9.8
- TI-2021-15227 A buffer overflow issue was discovered in the HMI3 Control Panel contained within the… CVSS 3.1CRITICAL 9.8
- TI-2021-15233 An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2021-37166 · CVE Program
- CVE-2021-37166 · NVD
- FIRST EPSS
- GHSA-4wc5-93xp-9wmv · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences