Read the docs
TI-2021-18857 Aliases CVE-2021-42577GHSA-fp56-3jcq-pm9w

An issue was discovered in Softing OPC UA C++ SDK before 5.70.

Priority LOW 35CWE-476Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-476.

Summary

An issue was discovered in Softing OPC UA C++ SDK before 5.70. A malformed OPC/UA message abort packet makes the client crash with a NULL pointer dereference.

Why it matters now

EPSS 0.00958 61st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:softing:datafeed_opc_suite:*:*:*:*:*:*:*:*up to 5.19VulnerableSofting
cpe:2.3:a:softing:opc_ua_c\+\+_software_development_kit:*:*:*:*:*:*:*:*before 5.70.0VulnerableSofting
cpe:2.3:a:softing:secure_integration_server:*:*:*:*:*:*:*:*up to 1.22VulnerableSofting
  • cpe:2.3:a:softing:datafeed_opc_suite:*:*:*:*:*:*:*:* Versions up to 5.19 Vulnerable ·Softing
  • cpe:2.3:a:softing:opc_ua_c\+\+_software_development_kit:*:*:*:*:*:*:*:* Versions before 5.70.0 Vulnerable ·Softing
  • cpe:2.3:a:softing:secure_integration_server:*:*:*:*:*:*:*:* Versions up to 1.22 Vulnerable ·Softing

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-42577
  2. 2026-10-03 Alias added: GHSA-fp56-3jcq-pm9w

References

  • TI-2021-17794 An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and… CVSS 3.1HIGH 7.5
  • TI-2021-17792 An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. CVSS 3.1HIGH 7.5
  • TI-2021-18699 An issue was discovered in Softing OPC UA C++ SDK before 5.70. CVSS 3.1MEDIUM 6.5