Path traversal in Triangle MicroWorks SCADA Data Gateway
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA.
Summary
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Triangle MicroWorks | SCADA Data Gateway | 5.01.01 | — | No fix listed | CNA |
- SCADA Data Gateway VendorTriangle MicroWorks Affected 5.01.01 Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:* | 5.01.01 | Vulnerable | Triangle MicroWorks |
- cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:* Versions 5.01.01 Vulnerable ·Triangle MicroWorks
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2022-0369
- 2026-10-03 Alias added: GHSA-jhmq-fqq2-2qvv
References
Advisory 1
More Triangle MicroWorks Scada Data Gateway vulnerabilities
- TI-2020-08523 Type confusion in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122… CVSS 3.1CRITICAL 9.8
- TI-2023-02050 On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated… CVSS 3.1CRITICAL 9.8
- TI-2023-20589 Missing authentication in Triangle MicroWorks SCADA Data Gateway CVSS 3.0CRITICAL 9.8
- TI-2023-20597 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information… CVSS 3.0HIGH 7.5
- TI-2023-20596 Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote… CVSS 3.0HIGH 7.2
- TI-2023-20592 Path traversal in Triangle MicroWorks SCADA Data Gateway CVSS 3.0HIGH 7.2
Sources
- CVE-2022-0369 · CVE Program
- CVE-2022-0369 · NVD
- FIRST EPSS
- GHSA-jhmq-fqq2-2qvv · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences