Read the docs
TI-2022-00783 Aliases CVE-2022-0878GHSA-qw95-rrxc-r294

Novel attack against the Combined Charging System (CCS) in electric vehicles to remotely cause a denial of service

Priority LOW 29CWE-306Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-306.

Summary

Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging. To exchange important messages such as the State of Charge (SoC) with the Electric Vehicle Supply Equipment (EVSE) CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY (HPGP) power-line communication (PLC) technology. The attack interrupts necessary control communication between the vehicle and charger, causing charging sessions to abort. The attack can be conducted wirelessly from a distance using electromagnetic interference, allowing individual vehicles or entire fleets to be disrupted simultaneously. In addition, the attack can be mounted with off-the-shelf radio hardware and minimal technical knowledge. With a power budget of 1 W, the attack is successful from around 47 m distance. The exploited behavior is a required part of the HomePlug Green PHY, DIN 70121 & ISO 15118 standards and all known implementations exhibit it. In addition to electric cars, Brokenwire affects electric ships, airplanes and heavy duty vehicles utilising these standards.

Why it matters now

EPSS 0.00494 42nd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Combined Charging SystemCombined Charging SystemCurrent version – 2.0—No fix listedCNA
Combined Charging SystemHomePlug GreenPHYCurrent version – 1.1—No fix listedCNA
  • Combined Charging System VendorCombined Charging System Affected Current version – 2.0 Fixed in — No fix listed CNA
  • HomePlug GreenPHY VendorCombined Charging System Affected Current version – 1.1 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:combined_charging_system_project:combined_charging_system_firmware:*:*:*:*:*:*:*:*up to 2.0VulnerableCombined Charging System Project
cpe:2.3:h:combined_charging_system_project:combined_charging_system:-:*:*:*:*:*:*:*not specified by NVDRunning onCombined Charging System Project

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-0878
  2. 2026-10-03 Alias added: GHSA-qw95-rrxc-r294

References

Sources