Read the docs
TI-2022-02742 Aliases CVE-2022-2969GHSA-c28m-8g89-fpm5

ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal

Priority MEDIUM 40CWE-22Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.02547 85th percentileScored 2026-11-07
Fix Fixed DIALink (Delta Industrial Automation): 1.5.0.0 Beta 4

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
deltawwDIALinkbefore 1.5.0.0 Beta 41.5.0.0 Beta 4Patch availableCNA
  • DIALink Vendordeltaww Affected before 1.5.0.0 Beta 4 Fixed in 1.5.0.0 Beta 4 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*before 1.5.0.0Vulnerabledeltaww
cpe:2.3:a:deltaww:dialink:1.5.0.0:beta3:*:*:*:*:*:*1.5.0.0 beta3Vulnerabledeltaww
  • cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:* Versions before 1.5.0.0 Vulnerable ·deltaww
  • cpe:2.3:a:deltaww:dialink:1.5.0.0:beta3:*:*:*:*:*:* Versions 1.5.0.0 beta3 Vulnerable ·deltaww

Remediation

  • Fix · CNA DIALink (Delta Industrial Automation) Fixed in 1.5.0.0 Beta 4

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-2969
  2. 2026-10-03 Alias added: GHSA-c28m-8g89-fpm5

References

  • TI-2025-36121 DIALink - Directory Traversal Authentication Bypass Vulnerability CVSS 3.1HIGH 7.3
  • TI-2025-36122 DIALink - Directory Traversal Authentication Bypass Vulnerability CVSS 3.1CRITICAL 10.0
  • TI-2022-02459 Hard-coded credentials in Delta Electronics Industrial Automation DIALink CVSS 3.1CRITICAL 9.8
  • TI-2021-16088 Cross-site scripting in Delta Electronics DIALink CVSS 3.1MEDIUM 5.5
  • TI-2021-16021 Cleartext transmission of sensitive information in Delta Electronics DIALink CVSS 3.1HIGH 8.8
  • TI-2021-16031 Cross-site scripting in Delta Electronics DIALink CVSS 3.1MEDIUM 5.5
See all 13 →

Sources