TI-2022-07051 Aliases CVE-2022-22807GHSA-jr23-8cgm-x898

Clickjacking in EcoStruxure EV Charging Expert : V4.0.0.13)

Priority LOW 34CWE-1021Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Spoofing
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-1021.

Summary

A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)

Why it matters now

EPSS 0.00938 61st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)—No fix listedCNA
  • EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) Vendor— Affected EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) Fixed in — No fix listed CNA

CPE configurations NVD · 14

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Show 4 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:*before 4.0.0.13VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:* Versions before 4.0.0.13 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.