Uncontrolled search path in Siemens SIMATIC Energy Manager Basic

Priority LOW 32CWE-427Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-427.

Summary

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Why it matters now

EPSS 0.00327 25th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC Energy Manager BasicAll versions < V7.3 Update 1—No fix listedCNA
SiemensSIMATIC Energy Manager PROAll versions < V7.3 Update 1—No fix listedCNA
  • SIMATIC Energy Manager Basic VendorSiemens Affected All versions < V7.3 Update 1 Fixed in — No fix listed CNA
  • SIMATIC Energy Manager PRO VendorSiemens Affected All versions < V7.3 Update 1 Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*before 7.3VulnerableSiemens
cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*7.3VulnerableSiemens
cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*before 7.3VulnerableSiemens
cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*7.3VulnerableSiemens
  • cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:* Versions before 7.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:* Versions 7.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:* Versions before 7.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:* Versions 7.3 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-23449
  2. 2026-10-03 Alias added: GHSA-fc86-6r8m-346f

References

  • TI-2022-07510 Deserialization of untrusted data in Siemens SIMATIC Energy Manager Basic CVSS 3.1CRITICAL 9.8
  • TI-2022-07508 Incorrect permission assignment in Siemens SIMATIC Energy Manager Basic CVSS 3.1HIGH 7.8

Sources