A CWE-665: Improper Initialization vulnerability exists that could cause information…
Priority LOW 35CWE-665Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA.
Summary
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Why it matters now
EPSS 0.01273 70th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | — | No fix listed | CNA |
- Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) Vendor— Affected Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:* | up to 15.0.0.22020 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:* Versions up to 15.0.0.22020 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2022-24316
- 2026-10-03 Alias added: GHSA-wgq3-h773-3ffp
References
More Schneider Electric Interactive Graphical Scada System Data Server vulnerabilities
- TI-2022-08193 Buffer overflow in Interactive Graphical SCADA System Data Server CVSS 3.1CRITICAL 9.8
- TI-2022-08195 Out-of-bounds read in Interactive Graphical SCADA System Data Server CVSS 3.1HIGH 7.5
- TI-2022-08194 Out-of-bounds read in Interactive Graphical SCADA System Data Server CVSS 3.1HIGH 7.5
- TI-2022-08192 Path traversal in Interactive Graphical SCADA System Data Server CVSS 3.1CRITICAL 9.8
- TI-2022-08191 Path traversal in Interactive Graphical SCADA System Data Server CVSS 3.1CRITICAL 9.8
- TI-2022-08190 Integer overflow in Interactive Graphical SCADA System Data Server CVSS 3.1CRITICAL 9.8
Sources
- CVE-2022-24316 · CVE Program
- CVE-2022-24316 · NVD
- FIRST EPSS
- GHSA-wgq3-h773-3ffp · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences