Read the docs
TI-2022-08284 Aliases CVE-2022-24408GHSA-c7jg-mh9j-jjqx

Improper privilege management in Siemens SINUMERIK MC

Priority LOW 33CWE-269Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Privilege escalation
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-269.

Summary

A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.

Why it matters now

EPSS 0.0021 11th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINUMERIK MCAll versions < V1.15 SP1—No fix listedCNA
SiemensSINUMERIK ONEAll versions < V6.15 SP1—No fix listedCNA
  • SINUMERIK MC VendorSiemens Affected All versions < V1.15 SP1 Fixed in — No fix listed CNA
  • SINUMERIK ONE VendorSiemens Affected All versions < V6.15 SP1 Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:o:siemens:sinumerik_mc_firmware:*:*:*:*:*:*:*:*before 1.15VulnerableSiemens
cpe:2.3:o:siemens:sinumerik_mc_firmware:1.15:-:*:*:*:*:*:*1.15VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_mc:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:*before 6.15VulnerableSiemens
cpe:2.3:o:siemens:sinumerik_one_firmware:6.15:-:*:*:*:*:*:*6.15VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:sinumerik_mc_firmware:*:*:*:*:*:*:*:* Versions before 1.15 Vulnerable ·Siemens
  • cpe:2.3:o:siemens:sinumerik_mc_firmware:1.15:-:*:*:*:*:*:* Versions 1.15 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_mc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:* Versions before 6.15 Vulnerable ·Siemens
  • cpe:2.3:o:siemens:sinumerik_one_firmware:6.15:-:*:*:*:*:*:* Versions 6.15 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-24408
  2. 2026-10-03 Alias added: GHSA-c7jg-mh9j-jjqx

References

  • TI-2023-24796 Use after free in Siemens SIMATIC Drive Controller CPU 1504D TF CVSS 3.1HIGH 7.5

Sources