TI-2022-10390 Aliases CVE-2022-27280GHSA-g562-prq5-956w

InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to…

Priority LOW 25CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
Cross-site scripting
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-79.

Summary

InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to contain a stored cross-site scripting (XSS) vulnerability via the web_exec parameter at /apply.cgi.

Why it matters now

EPSS 0.00575 47th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:inhandnetworks:inrouter_900_firmware:*:*:*:*:*:*:*:*before 1.0.0.r11700VulnerableInHand Networks
cpe:2.3:h:inhandnetworks:inrouter_900:-:*:*:*:*:*:*:*not specified by NVDRunning onInHand Networks
  • cpe:2.3:o:inhandnetworks:inrouter_900_firmware:*:*:*:*:*:*:*:* Versions before 1.0.0.r11700 Vulnerable ·InHand Networks
  • cpe:2.3:h:inhandnetworks:inrouter_900:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·InHand Networks

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-27280
  2. 2026-10-03 Alias added: GHSA-g562-prq5-956w

References

  • TI-2022-10380 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
  • TI-2022-10379 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
  • TI-2022-10387 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
  • TI-2022-10386 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
  • TI-2022-10385 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
  • TI-2022-10384 InHand Networks InRouter 900 Industrial 4G Router before v1.0.0.r11700 was discovered to… CVSS 3.1CRITICAL 9.8
See all 11 →

Sources