Read the docs
TI-2022-11131 Aliases CVE-2022-28377GHSA-6hxh-v9xw-6688

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0…

Priority LOW 35CWE-521Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-521.

Summary

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).

Why it matters now

EPSS 0.00966 61st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:verizon:lvskihp_indoorunit_firmware:3.4.66.162:*:*:*:*:*:*:*3.4.66.162VulnerableVerizon
cpe:2.3:h:verizon:lvskihp_indoorunit:-:*:*:*:*:*:*:*not specified by NVDRunning onVerizon
cpe:2.3:o:verizon:lvskihp_outdoorunit_firmware:3.33.101.0:*:*:*:*:*:*:*3.33.101.0VulnerableVerizon
cpe:2.3:h:verizon:lvskihp_outdoorunit:-:*:*:*:*:*:*:*not specified by NVDRunning onVerizon
  • cpe:2.3:o:verizon:lvskihp_indoorunit_firmware:3.4.66.162:*:*:*:*:*:*:* Versions 3.4.66.162 Vulnerable ·Verizon
  • cpe:2.3:h:verizon:lvskihp_indoorunit:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Verizon
  • cpe:2.3:o:verizon:lvskihp_outdoorunit_firmware:3.33.101.0:*:*:*:*:*:*:* Versions 3.33.101.0 Vulnerable ·Verizon
  • cpe:2.3:h:verizon:lvskihp_outdoorunit:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Verizon

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-28377
  2. 2026-10-03 Alias added: GHSA-6hxh-v9xw-6688

References

  • TI-2022-11127 Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not properly sanitize… CVSS 3.1CRITICAL 9.8
  • TI-2022-11123 Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not validate the user-provided… CVSS 3.1CRITICAL 9.8
  • TI-2022-11126 On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0… CVSS 3.1HIGH 7.5
  • TI-2022-11125 On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0… CVSS 3.1HIGH 7.5

Sources