Read the docs
TI-2022-11305 Aliases CVE-2022-28661GHSA-48j3-qgfp-gmrj

Out-of-bounds read in Siemens Simcenter Femap

Priority MEDIUM 40CWE-125Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114)

Why it matters now

EPSS 0.01201 68th percentileScored 2026-11-07
Fix Fixed Simcenter Femap (Siemens): V2022.1.2

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSimcenter Femapbefore V2022.1.2V2022.1.2Patch availableCNA
  • Simcenter Femap VendorSiemens Affected before V2022.1.2 Fixed in V2022.1.2 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*before 2022.1.2VulnerableSiemens
  • cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:* Versions before 2022.1.2 Vulnerable ·Siemens

Remediation

  • Fix · CNA Simcenter Femap (Siemens) Fixed in V2022.1.2

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-28661
  2. 2026-10-03 Alias added: GHSA-48j3-qgfp-gmrj

References

  • TI-2021-21091 Stack-based buffer overflow in Siemens Simcenter Femap V2020.2 CVSS 3.1HIGH 7.8
  • TI-2021-21088 Stack-based buffer overflow in Siemens Simcenter Femap V2020.2 CVSS 3.1HIGH 7.8
  • TI-2021-21087 Stack-based buffer overflow in Siemens Simcenter Femap V2020.2 CVSS 3.1HIGH 7.8
  • TI-2021-21451 Stack-based buffer overflow in Siemens Simcenter Femap CVSS 3.1HIGH 7.8
  • TI-2021-21095 Out-of-bounds write in Siemens Simcenter Femap CVSS 3.1HIGH 7.8
  • TI-2021-21094 Out-of-bounds write in Siemens Simcenter Femap V2020.2 CVSS 3.1HIGH 7.8
See all 77 →

Sources