Read the docs
TI-2022-11598 Aliases CVE-2022-29032GHSA-85m9-wggc-372h

Double free in Siemens JT2Go

Priority LOW 36CWE-415Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-415 and the CVSS impact.

Summary

A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Why it matters now

EPSS 0.00814 57th percentileScored 2026-11-07
Fix Fixed JT2Go (Siemens): V13.3.0.3Teamcenter Visualization V13.3 (Siemens): V13.3.0.3+1 more product

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensJT2Gobefore V13.3.0.3V13.3.0.3Patch availableCNA
SiemensTeamcenter Visualization V13.3before V13.3.0.3V13.3.0.3Patch availableCNA
SiemensTeamcenter Visualization V14.0before V14.0.0.1V14.0.0.1Patch availableCNA
  • JT2Go VendorSiemens Affected before V13.3.0.3 Fixed in V13.3.0.3 Patch available CNA
  • Teamcenter Visualization V13.3 VendorSiemens Affected before V13.3.0.3 Fixed in V13.3.0.3 Patch available CNA
  • Teamcenter Visualization V14.0 VendorSiemens Affected before V14.0.0.1 Fixed in V14.0.0.1 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*before 13.3.0.3VulnerableSiemens
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*13.3 to before 13.3.0.3; 14.0 to before 14.0.0.1VulnerableSiemens
  • cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* Versions before 13.3.0.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* Versions 13.3 to before 13.3.0.3; 14.0 to before 14.0.0.1 Vulnerable ·Siemens

Remediation

  • Fix · CNA JT2Go (Siemens) Fixed in V13.3.0.3
  • Fix · CNA Teamcenter Visualization V13.3 (Siemens) Fixed in V13.3.0.3
  • Fix · CNA Teamcenter Visualization V14.0 (Siemens) Fixed in V14.0.0.1

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-29032
  2. 2026-10-03 Alias added: GHSA-85m9-wggc-372h

References

  • TI-2020-16414 NULL pointer dereference in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16413 Type confusion in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16410 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16408 Heap-based buffer overflow in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16419 Out-of-bounds read in Siemens JT2Go CVSS 3.1HIGH 8.8
  • TI-2020-16418 Out-of-bounds write in Siemens JT2Go CVSS 3.1HIGH 8.8
See all 165 →

Sources