TI-2022-12548 Aliases CVE-2022-30313GHSA-qr79-94p4-h8hm

Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a…

Priority MEDIUM 41CWE-306Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-306.

Summary

Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00943 61st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:honeywell:safety_manager_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableHoneywell
cpe:2.3:h:honeywell:safety_manager:-:*:*:*:*:*:*:*not specified by NVDRunning onHoneywell
  • cpe:2.3:o:honeywell:safety_manager_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Honeywell
  • cpe:2.3:h:honeywell:safety_manager:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Honeywell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-30313
  2. 2026-10-03 Alias added: GHSA-qr79-94p4-h8hm

References

  • TI-2022-12550 Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient… CVSS 3.1CRITICAL 9.8
  • TI-2022-12551 Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data… CVSS 3.1MEDIUM 6.8
  • TI-2022-12549 Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. CVSS 3.1MEDIUM 4.6