Read the docs
TI-2022-13699 Aliases CVE-2022-31807GHSA-33j7-6p7h-f87g

Improper signature verification in Siemens Building X - Security Manager Edge Controller

Priority LOW 26CWE-347Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
Present
Impact type
Security bypass
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-347.

Summary

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00163 5th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensBuilding X - Security Manager Edge Controller (ACC-AP)all versions—No fix listedCNA
  • Building X - Security Manager Edge Controller (ACC-AP) VendorSiemens Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:siemens:sipass_integrated_ac5102_\(acc-g2\)_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:sipass_integrated_ac5102_\(acc-g2\):-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sipass_integrated_acc-ap_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:sipass_integrated_acc-ap:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:sipass_integrated_ac5102_\(acc-g2\)_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sipass_integrated_ac5102_\(acc-g2\):-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sipass_integrated_acc-ap_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sipass_integrated_acc-ap:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-31807
  2. 2026-10-03 Alias added: GHSA-33j7-6p7h-f87g

References

  • TI-2025-20329 Improper input validation in Siemens SiPass integrated AC5102 CVSS 4.0CRITICAL 9.4
  • TI-2025-20328 Improper input validation in Siemens SiPass integrated AC5102 CVSS 4.0CRITICAL 9.3
  • TI-2022-13700 Improper input validation in Siemens SiPass integrated AC5102 CVSS 3.1HIGH 7.8

Sources