Improper input validation in Schneider Electric Easergy P5
Key facts
- Attack vector
- Local
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- None · High · Low
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA.
Summary
A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior)
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schneider Electric | Easergy P5 | Firmware to before V01.401.102 | V01.401.102 | Patch available | CNA |
- Easergy P5 VendorSchneider Electric Affected Firmware to before V01.401.102 Fixed in V01.401.102 Patch available CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:* | up to 01.401.102 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
- cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:* Versions up to 01.401.102 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Remediation
- Fix · CNA Easergy P5 (Schneider Electric) Fixed in V01.401.102
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Schneider Electric Easergy P5 V01.401.102
3 records Highest priority Priority MEDIUM 1 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2022-15564 Buffer overflow in Schneider Electric Easergy P5Priority MEDIUM 45
- TI-2022-15565 Broken or risky cryptographic algorithm in Schneider Electric Easergy P5Priority LOW 30
Timeline
- 2026-10-02 Threatist record created from CVE-2022-34758
- 2026-10-03 Alias added: GHSA-rw6g-9gmq-76ff
More Schneider Electric Easergy P5 Firmware vulnerabilities
- TI-2022-15564 Buffer overflow in Schneider Electric Easergy P5 CVSS 3.1CRITICAL 9.8
- TI-2022-06973 Buffer overflow in Easergy P5 CVSS 3.1HIGH 8.8
- TI-2022-06972 Hard-coded credentials in Schneider Electric Easergy P5 CVSS 3.1HIGH 7.5
- TI-2022-15565 Broken or risky cryptographic algorithm in Schneider Electric Easergy P5 CVSS 3.1MEDIUM 6.7
Sources
- CVE-2022-34758 · CVE Program
- CVE-2022-34758 · NVD
- FIRST EPSS
- GHSA-rw6g-9gmq-76ff · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences