Read the docs
TI-2022-17253 Aliases CVE-2022-37060GHSA-rvx6-587f-87jf

FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to…

Priority MEDIUM 51CWE-22Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-22 and the CVSS impact.

Summary

FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.

Why it matters now

EPSS 0.19341 97th percentileScored 2026-11-07
Public exploit Yes 2 exploit referencesTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:flir:flir_ax8_firmware:*:*:*:*:*:*:*:*up to 1.46.16VulnerableTeledyne FLIR
cpe:2.3:h:flir:flir_ax8:-:*:*:*:*:*:*:*not specified by NVDRunning onTeledyne FLIR
  • cpe:2.3:o:flir:flir_ax8_firmware:*:*:*:*:*:*:*:* Versions up to 1.46.16 Vulnerable ·Teledyne FLIR
  • cpe:2.3:h:flir:flir_ax8:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Teledyne FLIR

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-37060
  2. 2026-10-03 Alias added: GHSA-rvx6-587f-87jf

References

  • TI-2022-17254 All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to… CVSS 3.1CRITICAL 9.8
  • TI-2018-15364 FLIR AX8 Thermal Camera 1.32.16 Hard-Coded Credentials Authentication Bypass CVSS 4.0CRITICAL 9.3
  • TI-2018-15365 FLIR AX8 Thermal Camera 1.32.16 Unauthenticated RTSP Stream Disclosure CVSS 4.0HIGH 8.7
  • TI-2025-04595 Teledyne FLIR AX8 settingsregional.php setDataTime command injection CVSS 4.0HIGH 8.7
  • TI-2022-03997 Teledyne FLIR AX8 Web Service palette.php command injection CVSS 4.0MEDIUM 6.9
  • TI-2023-27944 Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows… CVSS 3.1CRITICAL 9.8
See all 13 →

Sources