Read the docs
TI-2022-20065 Aliases CVE-2022-41670GHSA-fx46-8pxx-3pfj

Path traversal in Schneider Electric EcoStruxure Operator Terminal Expert

Priority LOW 35CWE-22Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00207 10th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure Operator Terminal ExpertV3.3 – Hotfix 1—No fix listedCNA
Schneider ElectricPro-face BLUEV3.3 – Hotfix 1—No fix listedCNA
  • EcoStruxure Operator Terminal Expert VendorSchneider Electric Affected V3.3 – Hotfix 1 Fixed in — No fix listed CNA
  • Pro-face BLUE VendorSchneider Electric Affected V3.3 – Hotfix 1 Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*before 3.3VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:*3.3VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:*3.3 hotfix1VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*before 3.3VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:*3.3VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:*3.3 hotfix1VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:* Versions before 3.3 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:* Versions 3.3 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:* Versions 3.3 hotfix1 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:* Versions before 3.3 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:* Versions 3.3 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:* Versions 3.3 hotfix1 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-41670
  2. 2026-10-03 Alias added: GHSA-fx46-8pxx-3pfj

References

  • TI-2020-06020 Path traversal in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior CVSS 3.1CRITICAL 9.8
  • TI-2020-17151 Improper input validation in EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A… CVSS 3.1CRITICAL 9.8
  • TI-2023-00994 Code injection in Schneider Electric EcoStruxure™ Operator Terminal Expert CVSS 3.1HIGH 7.8
  • TI-2020-06017 Path traversal in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior CVSS 3.1HIGH 7.8
  • TI-2022-20066 SQL injection in Schneider Electric EcoStruxure Operator Terminal Expert CVSS 3.1HIGH 7.8
  • TI-2022-20062 Path traversal in Schneider Electric EcoStruxure Operator Terminal Expert CVSS 3.1HIGH 7.8
See all 11 →

Sources