Read the docs
TI-2022-20803 Aliases CVE-2022-42786GHSA-ffmc-cj3h-9wwj

Wiesemann & Theis: XSS vulnerability in web interface of the Com-Server family

Priority LOW 25CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
Cross-site scripting
Confidentiality · integrity · availability
Low · Low · None
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-79.

Summary

Multiple W&T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.0058 47th percentileScored 2026-11-07
Fix Fixed Com-Server LC (Wiesemann & Theis): 1.48Com-Server PoE 3 x Isolated (Wiesemann & Theis): 1.48+15 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Wiesemann & TheisCom-Server LC1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisCom-Server PoE 3 x Isolated1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisCom-Server 20mA1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisCom-Server ++1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisAT-Modem-Emulator1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisCom-Server UL1.0 to before 1.481.48Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 100BaseFX1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 100BaseLX1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Office 1 Port1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Office 4 Port1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Industry1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed OEM1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Compact1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Isolated1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 19" 1Port1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 19" 4Port1.0 to before 1.761.76Patch availableCNA
Wiesemann & TheisCom-Server Highspeed PoE1.0 to before 1.761.76Patch availableCNA
  • Com-Server LC VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • Com-Server PoE 3 x Isolated VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • Com-Server 20mA VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • Com-Server ++ VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • AT-Modem-Emulator VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • Com-Server UL VendorWiesemann & Theis Affected 1.0 to before 1.48 Fixed in 1.48 Patch available CNA
  • Com-Server Highspeed 100BaseFX VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed 100BaseLX VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed Office 1 Port VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed Office 4 Port VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed Industry VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed OEM VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed Compact VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed Isolated VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed 19" 1Port VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed 19" 4Port VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA
  • Com-Server Highspeed PoE VendorWiesemann & Theis Affected 1.0 to before 1.76 Fixed in 1.76 Patch available CNA

CPE configurations NVD · 34

CPEVersionsRoleVendor
cpe:2.3:o:wut:at-modem-emulator_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:at-modem-emulator:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_\+\+_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_\+\+:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_20ma_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_20ma:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_100basefx_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_100basefx:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_100baselx_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_100baselx:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
  • cpe:2.3:o:wut:at-modem-emulator_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:at-modem-emulator:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_\+\+_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_\+\+:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_20ma_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_20ma:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_100basefx_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_100basefx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_100baselx_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_100baselx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
Show 24 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:wut:com-server_highspeed_19\"_1port_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_19\"_1port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_19\"_4port_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_19\"_4port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_compact_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_compact:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_industry_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_industry:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_isolated_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_isolated:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_oem_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_oem:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_office_1port_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_office_1port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_office_4port_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_office_4port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_poe_firmware:*:*:*:*:*:*:*:*before 1.76VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_poe:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_lc_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_lc:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_ul_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_ul:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_poe_3x_isolated_firmware:*:*:*:*:*:*:*:*before 1.48VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_poe_3x_isolated:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_19\"_1port_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_19\"_1port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_19\"_4port_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_19\"_4port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_compact_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_compact:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_industry_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_industry:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_isolated_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_isolated:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_oem_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_oem:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_office_1port_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_office_1port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_office_4port_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_office_4port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_poe_firmware:*:*:*:*:*:*:*:* Versions before 1.76 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_poe:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_lc_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_lc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_ul_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_ul:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_poe_3x_isolated_firmware:*:*:*:*:*:*:*:* Versions before 1.48 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_poe_3x_isolated:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis

Remediation

  • Fix · CNA Com-Server LC (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA Com-Server PoE 3 x Isolated (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA Com-Server 20mA (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA Com-Server ++ (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA AT-Modem-Emulator (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA Com-Server UL (Wiesemann & Theis) Fixed in 1.48
  • Fix · CNA Com-Server Highspeed 100BaseFX (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed 100BaseLX (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed Office 1 Port (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed Office 4 Port (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed Industry (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed OEM (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed Compact (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed Isolated (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed 19" 1Port (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed 19" 4Port (Wiesemann & Theis) Fixed in 1.76
  • Fix · CNA Com-Server Highspeed PoE (Wiesemann & Theis) Fixed in 1.76

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Wiesemann & Theis AT-Modem-Emulator, Com-Server ++ and 15 more products 1.48, 1.76

    3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2022-20802 Wiesemann & Theis: Authentication bypass in Com-Server familyPriority MEDIUM 44
    • TI-2022-20804 Wiesemann & Theis: Small number space for allocating session id in Com-Server familyPriority MEDIUM 40

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-42786
  2. 2026-10-03 Alias added: GHSA-ffmc-cj3h-9wwj

References

  • TI-2022-20802 Wiesemann & Theis: Authentication bypass in Com-Server family CVSS 3.1CRITICAL 9.8
  • TI-2022-20804 Wiesemann & Theis: Small number space for allocating session id in Com-Server family CVSS 3.1HIGH 8.8

Sources