Read the docs
TI-2023-01082 Aliases CVE-2023-1144GHSA-ggfq-85jm-276p

Incorrect authorization in Delta Electronics InfraSuite Device Master

Priority MEDIUM 41CWE-863Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-863.

Summary

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00645 51st percentileScored 2026-11-07
Fix Fixed InfraSuite Device Master (Delta Electronics): 1.0.5

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Delta ElectronicsInfraSuite Device Masterbefore 1.0.51.0.5Patch availableCNA
  • InfraSuite Device Master VendorDelta Electronics Affected before 1.0.5 Fixed in 1.0.5 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*before 1.0.5Vulnerabledeltaww
  • cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:* Versions before 1.0.5 Vulnerable ·deltaww

Remediation

  • Fix · CNA InfraSuite Device Master (Delta Electronics) Fixed in 1.0.5

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Delta Electronics InfraSuite Device Master 1.0.5

    13 records Highest priority Priority HIGH 1 HIGH, 8 MEDIUM, 4 LOW

    Other records, highest priority first

    • TI-2023-01071 Deserialization of untrusted data in Delta Electronics InfraSuite Device MasterPriority HIGH 80
    • TI-2023-01078 Missing authentication in Delta Electronics InfraSuite Device MasterPriority MEDIUM 51
    • TI-2023-01080 Path traversal in Delta Electronics InfraSuite Device MasterPriority MEDIUM 50

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-1144
  2. 2026-10-03 Alias added: GHSA-ggfq-85jm-276p
  3. 2026-10-20 EPSS moved to the 50th–90th percentile

References

  • TI-2021-16010 Delta Electronics DOPSoft 2 Out-of-Bounds Write KEVCVSS 3.1HIGH 7.8
  • TI-2023-01071 Deserialization of untrusted data in Delta Electronics InfraSuite Device Master CVSS 3.1CRITICAL 9.8
  • TI-2024-04235 Delta Electronics DIAEnergie SQL Injection CVSS 3.1HIGH 7.5
  • TI-2024-04234 Delta Electronics DIAEnergie SQL Injection CVSS 3.1CRITICAL 9.8
  • TI-2022-20149 Path traversal in Delta Electronics InfraSuite Device Master CVSS 3.1CRITICAL 9.8
  • TI-2024-18749 Delta Electronics DIAEnergie Path traversal CVSS 3.1HIGH 8.1
See all 229 →