Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-22 and the CVSS impact.
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi | up to 1.4.24 | — | No fix listed | CNA |
- FDS101 for FAdC/FAdCi VendorFrauscher Affected up to 1.4.24 Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2023-4152
- 2026-10-03 Alias added: GHSA-v7hg-r7jc-rmvp
References
More Frauscher Diagnostic System 101 vulnerabilities
- TI-2023-03967 Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability CVSS 3.1CRITICAL 9.8
- TI-2023-02699 Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability CVSS 3.1HIGH 7.5
- TI-2023-03968 Frauscher FDS101 for FAdC/FAdCi SQL injection vulnerability CVSS 3.1MEDIUM 5.3
Sources
- CVE-2023-4152 · CVE Program
- CVE-2023-4152 · NVD
- FIRST EPSS
- GHSA-v7hg-r7jc-rmvp · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences