Read the docs
TI-2023-09288 Aliases CVE-2023-23446GHSA-qq8q-67x7-25jm

Improper access control in SICK FTMG-ESD15AXX AIR FLOW SENSOR

Priority MEDIUM 41CWE-284Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-284.

Summary

Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00891 59th percentileScored 2026-11-07
Fix Fixed SICK FTMG-ESD15AXX AIR FLOW SENSOR (SICK AG): v3.0.0.131.ReleaseSICK FTMG-ESD20AXX AIR FLOW SENSOR (SICK AG): v3.0.0.131.Release+5 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SICK AGSICK FTMG-ESD15AXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESD20AXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESD25AXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESN40SXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESN50SXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESR40SXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
SICK AGSICK FTMG-ESR50SXX AIR FLOW SENSORbefore v3.0.0.131.Releasev3.0.0.131.ReleasePatch availableCNA
  • SICK FTMG-ESD15AXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESD20AXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESD25AXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESN40SXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESN50SXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESR40SXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA
  • SICK FTMG-ESR50SXX AIR FLOW SENSOR VendorSICK AG Affected before v3.0.0.131.Release Fixed in v3.0.0.131.Release Patch available CNA

CPE configurations NVD · 14

CPEVersionsRoleVendor
cpe:2.3:o:sick:ftmg-esd20axx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esd20axx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
cpe:2.3:o:sick:ftmg-esd25axx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esd25axx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
cpe:2.3:o:sick:ftmg-esn40sxx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esn40sxx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
cpe:2.3:o:sick:ftmg-esn50sxx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esn50sxx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
cpe:2.3:o:sick:ftmg-esr50sxx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esr50sxx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
  • cpe:2.3:o:sick:ftmg-esd20axx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esd20axx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
  • cpe:2.3:o:sick:ftmg-esd25axx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esd25axx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
  • cpe:2.3:o:sick:ftmg-esn40sxx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esn40sxx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
  • cpe:2.3:o:sick:ftmg-esn50sxx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esn50sxx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
  • cpe:2.3:o:sick:ftmg-esr50sxx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esr50sxx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
Show 4 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:sick:ftmg-esr40sxx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esr40sxx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
cpe:2.3:o:sick:ftmg-esd15axx_firmware:*:*:*:*:*:*:*:*before 2.0VulnerableSICK AG
cpe:2.3:h:sick:ftmg-esd15axx:-:*:*:*:*:*:*:*not specified by NVDRunning onSICK AG
  • cpe:2.3:o:sick:ftmg-esr40sxx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esr40sxx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG
  • cpe:2.3:o:sick:ftmg-esd15axx_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·SICK AG
  • cpe:2.3:h:sick:ftmg-esd15axx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·SICK AG

Remediation

  • Fix · CNA SICK FTMG-ESD15AXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESD20AXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESD25AXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESN40SXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESN50SXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESR40SXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release
  • Fix · CNA SICK FTMG-ESR50SXX AIR FLOW SENSOR (SICK AG) Fixed in v3.0.0.131.Release

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    SICK FTMG-ESD15AXX AIR FLOW SENSOR, SICK FTMG-ESD20AXX AIR FLOW SENSOR and 5 more products — sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf

    8 records Highest priority Priority MEDIUM 5 MEDIUM, 3 LOW

    Other records, highest priority first

    • TI-2023-09292 Improper authentication in SICK FTMG-ESD15AXX AIR FLOW SENSORPriority MEDIUM 43
    • TI-2023-15027 Uncontrolled resource consumption in SICK FTMG-ESD15AXX AIR FLOW SENSORPriority MEDIUM 41
    • TI-2023-09289 Uncontrolled resource consumption in SICK FTMG-ESD15AXX AIR FLOW SENSORPriority MEDIUM 41

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-23446
  2. 2026-10-03 Alias added: GHSA-qq8q-67x7-25jm

References

  • TI-2023-09292 Improper authentication in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1CRITICAL 9.8
  • TI-2023-15027 Uncontrolled resource consumption in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1HIGH 7.5
  • TI-2023-09289 Uncontrolled resource consumption in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1HIGH 7.5
  • TI-2023-09287 Improper access control in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1HIGH 7.5
  • TI-2023-15026 Cleartext storage of sensitive information in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1HIGH 7.5
  • TI-2023-09291 Observable discrepancy in SICK FTMG-ESD15AXX AIR FLOW SENSOR CVSS 3.1MEDIUM 5.3
See all 7 →

Sources