Read the docs
TI-2023-10123 Aliases CVE-2023-24502GHSA-fqm3-34q3-vw23

Electra Central AC unit – Easily calculated password

Priority LOW 34CWE-521Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
High
Impact type
Security bypass, Information disclosure
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-521 and CWE-326.

Summary

Electra Central AC unit – The unit opens an AP with an easily calculated password.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00171 6th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
ElectraElectra Central AC unitUpdate to the latest version and later—No fix listedCNA
  • Electra Central AC unit VendorElectra Affected Update to the latest version and later Fixed in — No fix listed CNA

CPE configurations NVD · 5

CPEVersionsRoleVendor
cpe:2.3:o:electra-air:central_ac_unit_firmware:v4:*:*:*:*:*:*:*v4VulnerableElectra
cpe:2.3:o:electra-air:central_ac_unit_firmware:v5:*:*:*:*:*:*:*v5VulnerableElectra
cpe:2.3:o:electra-air:central_ac_unit_firmware:v7:*:*:*:*:*:*:*v7VulnerableElectra
cpe:2.3:o:electra-air:central_ac_unit_firmware:v8:*:*:*:*:*:*:*v8VulnerableElectra
cpe:2.3:h:electra-air:central_ac_unit:-:*:*:*:*:*:*:*not specified by NVDRunning onElectra
  • cpe:2.3:o:electra-air:central_ac_unit_firmware:v4:*:*:*:*:*:*:* Versions v4 Vulnerable ·Electra
  • cpe:2.3:o:electra-air:central_ac_unit_firmware:v5:*:*:*:*:*:*:* Versions v5 Vulnerable ·Electra
  • cpe:2.3:o:electra-air:central_ac_unit_firmware:v7:*:*:*:*:*:*:* Versions v7 Vulnerable ·Electra
  • cpe:2.3:o:electra-air:central_ac_unit_firmware:v8:*:*:*:*:*:*:* Versions v8 Vulnerable ·Electra
  • cpe:2.3:h:electra-air:central_ac_unit:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Electra

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-24502
  2. 2026-10-03 Alias added: GHSA-fqm3-34q3-vw23

References

  • TI-2023-10122 Hard-coded credentials in Electra Central AC unit CVSS 3.1CRITICAL 9.8
  • TI-2023-10125 Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized… CVSS 3.1HIGH 7.5
  • TI-2023-10121 Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW CVSS 3.1HIGH 7.5

Sources