Read the docs
TI-2023-12567 Aliases CVE-2023-27977GHSA-8c9m-95jr-9f2r

Insufficient verification of data authenticity in Schneider Electric IGSS Data Server

Priority LOW 34CWE-345Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
None · Low · Low
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-345.

Summary

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00243 15th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricIGSS Data Server(IGSSdataServer.exe)V – 16.0.0.23040—No fix listedCNA
Schneider ElectricIGSS Dashboard (DashBoard.exe)V – 16.0.0.23040—No fix listedCNA
Schneider ElectricCustom Reports (RMS16.dll)V – 16.0.0.23040—No fix listedCNA
  • IGSS Data Server(IGSSdataServer.exe) VendorSchneider Electric Affected V – 16.0.0.23040 Fixed in — No fix listed CNA
  • IGSS Dashboard (DashBoard.exe) VendorSchneider Electric Affected V – 16.0.0.23040 Fixed in — No fix listed CNA
  • Custom Reports (RMS16.dll) VendorSchneider Electric Affected V – 16.0.0.23040 Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*up to 16.0.0.23040VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*up to 16.0.0.23040VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*up to 16.0.0.23040VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:* Versions up to 16.0.0.23040 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:* Versions up to 16.0.0.23040 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:* Versions up to 16.0.0.23040 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-27977
  2. 2026-10-03 Alias added: GHSA-8c9m-95jr-9f2r

References

  • TI-2023-12568 Deserialization of untrusted data in Schneider Electric IGSS Data Server CVSS 3.1HIGH 7.8
  • TI-2023-12570 Missing authentication in Schneider Electric IGSS Data Server CVSS 3.1HIGH 8.8
  • TI-2023-12574 Improper input validation in Schneider Electric IGSS Data Server CVSS 3.1HIGH 8.8
  • TI-2023-12571 Path traversal in Schneider Electric IGSS Data Server CVSS 3.1HIGH 8.8
  • TI-2023-12572 Insufficient verification of data authenticity in Schneider Electric IGSS Data Server CVSS 3.1HIGH 8.8
  • TI-2023-12573 Missing authentication in Schneider Electric IGSS Data Server CVSS 3.1MEDIUM 6.5
See all 7 →

Sources