Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · None · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA.
Summary
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Rockwell | FactoryTalk Linx | 6.20; 6.30 | — | No fix listed | CNA |
- FactoryTalk Linx VendorRockwell Affected 6.20; 6.30 Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2023-29464
- 2026-10-03 Alias added: GHSA-4v9x-wfx7-57r9
References
More Rockwell Factorytalk Linx vulnerabilities
- TI-2020-04730 Resource allocation without limits in Rockwell FactoryTalk Linx CVSS 3.1HIGH 7.5
- TI-2020-09660 Improper input validation in FactoryTalk Linx, RSLinx Classic, Connected Components… CVSS 3.1CRITICAL 9.8
- TI-2020-04729 Improper handling of exceptional conditions in Rockwell FactoryTalk Linx CVSS 3.1HIGH 7.5
- TI-2020-16577 Heap-based buffer overflow in FactoryTalk Linx CVSS 3.1CRITICAL 9.8
- TI-2020-09662 Path traversal in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench… CVSS 3.1HIGH 7.5
- TI-2020-09658 Improper input validation in FactoryTalk Linx, RSLinx Classic, Connected Components… CVSS 3.1HIGH 8.1
Sources
- CVE-2023-29464 · CVE Program
- CVE-2023-29464 · NVD
- FIRST EPSS
- GHSA-4v9x-wfx7-57r9 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences