Read the docs
TI-2023-18243 Aliases CVE-2023-36380GHSA-mmpj-f59m-vxp4

Hard-coded credentials in Siemens CP-8031 MASTER MODULE

Priority MEDIUM 49CWE-798Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-798.

Summary

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00408 35th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensCP-8031 MASTER MODULEAll versions < CPCI85 V05.11 (only with activated debug support)—No fix listedCNA
SiemensCP-8050 MASTER MODULEAll versions < CPCI85 V05.11 (only with activated debug support)—No fix listedCNA
  • CP-8031 MASTER MODULE VendorSiemens Affected All versions < CPCI85 V05.11 (only with activated debug support) Fixed in — No fix listed CNA
  • CP-8050 MASTER MODULE VendorSiemens Affected All versions < CPCI85 V05.11 (only with activated debug support) Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:siemens:cp-8050_firmware:*:*:*:*:cpci85:*:*:*before 05.11VulnerableSiemens
cpe:2.3:h:siemens:cp-8050:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:cp-8031_firmware:*:*:*:*:cpci85:*:*:*before 05.11VulnerableSiemens
cpe:2.3:h:siemens:cp-8031:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:cp-8050_firmware:*:*:*:*:cpci85:*:*:* Versions before 05.11 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:cp-8050:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:cp-8031_firmware:*:*:*:*:cpci85:*:*:* Versions before 05.11 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:cp-8031:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-36380
  2. 2026-10-03 Alias added: GHSA-mmpj-f59m-vxp4

References

  • TI-2023-13029 Command injection in Siemens CP-8031 MASTER MODULE CVSS 3.1CRITICAL 9.8
  • TI-2023-22887 Path traversal in Siemens CP-8031 MASTER MODULE CVSS 3.1HIGH 8.8

Sources