Read the docs
TI-2023-18827 Aliases CVE-2023-37194GHSA-cjgq-qwc4-hf8h

Improper access control in Siemens SIMATIC CP 1604

Priority LOW 31CWE-284Published · Updated

Key facts

Attack vector
Local
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-284.

Summary

A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00194 9th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC CP 1604All versions—No fix listedCNA
SiemensSIMATIC CP 1616All versions—No fix listedCNA
SiemensSIMATIC CP 1623All versions—No fix listedCNA
SiemensSIMATIC CP 1626All versions—No fix listedCNA
SiemensSIMATIC CP 1628All versions—No fix listedCNA
  • SIMATIC CP 1604 VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • SIMATIC CP 1616 VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • SIMATIC CP 1623 VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • SIMATIC CP 1626 VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • SIMATIC CP 1628 VendorSiemens Affected All versions Fixed in — No fix listed CNA

CPE configurations NVD · 10

CPEVersionsRoleVendor
cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-37194
  2. 2026-10-03 Alias added: GHSA-cjgq-qwc4-hf8h

References

  • TI-2019-10399 Uncontrolled resource consumption in Siemens Development/Evaluation Kits for PROFINET IO… CVSS 3.1HIGH 7.5