Read the docs
TI-2023-19731 Aliases CVE-2023-38334GHSA-489g-54j3-q6rq

Omnis Studio 10.22.00 has incorrect access control.

Priority HIGH 68CWE-276Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

Omnis Studio 10.22.00 has incorrect access control. It advertises an irreversible feature for locking classes within Omnis libraries: it should be no longer possible to delete, view, change, copy, rename, duplicate, or print a locked class. Due to implementation issues, locked classes in Omnis libraries can be unlocked, and thus further analyzed and modified by Omnis Studio. This allows for further analyzing and also deleting, viewing, changing, copying, renaming, duplicating, or printing previously locked Omnis classes. This violates the expected behavior of an "irreversible operation."

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00881 59th percentileScored 2026-11-07
Public exploit Yes 2 exploit referencesTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:omnis:studio:10.22.00:*:*:*:*:*:*:*10.22.00VulnerableOmnis
  • cpe:2.3:a:omnis:studio:10.22.00:*:*:*:*:*:*:* Versions 10.22.00 Vulnerable ·Omnis

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-38334
  2. 2026-10-03 Alias added: GHSA-489g-54j3-q6rq

References

  • TI-2023-19732 Omnis Studio 10.22.00 has incorrect access control. CVSS 3.1MEDIUM 5.3
  • TI-2000-00449 Omnis Studio 2.4 uses weak encryption (trivial encoding) for encrypting database fields. CVSS 2.0HIGH 10.0