Stack-based buffer overflow in Siemens Parasolid V35.0
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.
Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 | before V35.0.262 | V35.0.262 | Patch available | CNA |
| Siemens | Parasolid V35.1 | before V35.1.250 | V35.1.250 | Patch available | CNA |
| Siemens | Parasolid V36.0 | before V36.0.169 | V36.0.169 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2201 | before V2201.0009 | V2201.0009 | Patch available | CNA |
| Siemens | Tecnomatix Plant Simulation V2302 | before V2302.0003 | V2302.0003 | Patch available | CNA |
- Parasolid V35.0 VendorSiemens Affected before V35.0.262 Fixed in V35.0.262 Patch available CNA
- Parasolid V35.1 VendorSiemens Affected before V35.1.250 Fixed in V35.1.250 Patch available CNA
- Parasolid V36.0 VendorSiemens Affected before V36.0.169 Fixed in V36.0.169 Patch available CNA
- Tecnomatix Plant Simulation V2201 VendorSiemens Affected before V2201.0009 Fixed in V2201.0009 Patch available CNA
- Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0003 Fixed in V2302.0003 Patch available CNA
Remediation
- Fix · CNA Parasolid V35.0 (Siemens) Fixed in V35.0.262
- Fix · CNA Parasolid V35.1 (Siemens) Fixed in V35.1.250
- Fix · CNA Parasolid V36.0 (Siemens) Fixed in V36.0.169
- Fix · CNA Tecnomatix Plant Simulation V2201 (Siemens) Fixed in V2201.0009
- Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0003
Timeline
- 2026-10-02 Threatist record created from CVE-2023-45601
- 2026-10-03 Alias added: GHSA-r7vr-7m7q-pqv6
References
More Siemens Parasolid vulnerabilities
- TI-2022-22893 Out-of-bounds read in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2022-22891 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2024-21079 Out-of-bounds write in Siemens Parasolid V35.1 CVSS 3.1HIGH 7.8
- TI-2023-21659 Out-of-bounds write in Siemens Parasolid V34.1 CVSS 3.1HIGH 7.8
- TI-2022-22892 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2022-22889 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
Sources
- CVE-2023-45601 · CVE Program
- CVE-2023-45601 · NVD
- FIRST EPSS
- GHSA-r7vr-7m7q-pqv6 · GitHub Advisory Database · CC BY 4.0