OS command injection in Synology Camera Firmware
Key facts
- Attack vector
- Network
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-78.
Summary
A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the IP block functionality. This allows remote authenticated users with administrator privileges to execute arbitrary commands via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.7-0298 may be affected: BC500 and TC500.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Synology | Camera Firmware | 1.0 to before 1.0.7-0298 | 1.0.7-0298 | Patch available | CNA |
- Camera Firmware VendorSynology Affected 1.0 to before 1.0.7-0298 Fixed in 1.0.7-0298 Patch available CNA
CPE configurations NVD · 4
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:synology:bc500_firmware:*:*:*:*:*:*:*:* | before 1.0.7-0298 | Vulnerable | Synology |
| cpe:2.3:h:synology:bc500:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Synology |
| cpe:2.3:o:synology:tc500_firmware:*:*:*:*:*:*:*:* | before 1.0.7-0298 | Vulnerable | Synology |
| cpe:2.3:h:synology:tc500:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Synology |
- cpe:2.3:o:synology:bc500_firmware:*:*:*:*:*:*:*:* Versions before 1.0.7-0298 Vulnerable ·Synology
- cpe:2.3:h:synology:bc500:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Synology
- cpe:2.3:o:synology:tc500_firmware:*:*:*:*:*:*:*:* Versions before 1.0.7-0298 Vulnerable ·Synology
- cpe:2.3:h:synology:tc500:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Synology
Remediation
- Fix · CNA Camera Firmware (Synology) Fixed in 1.0.7-0298
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Advisory ·
Synology Camera Firmware — Synology-SA-23:15 Synology Camera (PWN2OWN 2023)
6 records Highest priority Priority MEDIUM 1 MEDIUM, 5 LOW
Other records, highest priority first
- TI-2024-26302 Buffer overflow in Synology Camera FirmwarePriority MEDIUM 52
- TI-2024-26304 OS command injection in Synology Camera FirmwarePriority LOW 37
- TI-2024-26303 Authentication bypass by spoofing in Synology Camera FirmwarePriority LOW 36
Timeline
- 2026-10-02 Threatist record created from CVE-2023-47802
- 2026-10-03 Alias added: GHSA-h7wv-22h8-mr42
References
More Synology Bc500 Firmware vulnerabilities
- TI-2023-05285 A vulnerability regarding use of externally-controlled format string is found in the cgi… CVSS 3.1CRITICAL 9.8
- TI-2024-26302 Buffer overflow in Synology Camera Firmware CVSS 3.1CRITICAL 9.8
- TI-2024-10315 Out-of-bounds read in Synology Camera Firmware CVSS 3.1CRITICAL 9.8
- TI-2024-26304 OS command injection in Synology Camera Firmware CVSS 3.1HIGH 7.2
- TI-2024-26303 Authentication bypass by spoofing in Synology Camera Firmware CVSS 3.1HIGH 7.5
- TI-2024-05077 Buffer overflow in Synology Camera Firmware CVSS 3.1MEDIUM 6.5
Sources
- CVE-2023-47802 · CVE Program
- CVE-2023-47802 · NVD
- FIRST EPSS
- GHSA-h7wv-22h8-mr42 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences