Read the docs
TI-2023-29212 Aliases CVE-2023-52891GHSA-gccj-rgh5-5x96

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions <…

Priority LOW 30CWE-1325Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · Low
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00465 40th percentileScored 2026-11-07
Fix Fixed SIMATIC Energy Manager Basic (Siemens): V7.5SIMATIC Energy Manager PRO (Siemens): V7.5+1 more product

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC Energy Manager Basicbefore V7.5V7.5Patch availableCNA
SiemensSIMATIC Energy Manager PRObefore V7.5V7.5Patch availableCNA
SiemensSIMATIC IPC DiagBaseall versions—No fix listedCNA
SiemensSIMATIC IPC DiagMonitorall versions—No fix listedCNA
SiemensSIMIT V10all versions—No fix listedCNA
SiemensSIMIT V11before V11.1V11.1Patch availableCNA
  • SIMATIC Energy Manager Basic VendorSiemens Affected before V7.5 Fixed in V7.5 Patch available CNA
  • SIMATIC Energy Manager PRO VendorSiemens Affected before V7.5 Fixed in V7.5 Patch available CNA
  • SIMATIC IPC DiagBase VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMATIC IPC DiagMonitor VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMIT V10 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMIT V11 VendorSiemens Affected before V11.1 Fixed in V11.1 Patch available CNA

CPE names CISA-ADP · 6

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*——Siemens
cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*——Siemens
cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*not specified by CISA-ADP—Siemens
cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*not specified by CISA-ADP—Siemens
cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:*——Siemens
cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:*——Siemens
  • cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:* Versions — — ·Siemens
  • cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:* Versions — — ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Siemens
  • cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:* Versions — — ·Siemens
  • cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:* Versions — — ·Siemens

Remediation

  • Fix · CNA SIMATIC Energy Manager Basic (Siemens) Fixed in V7.5
  • Fix · CNA SIMATIC Energy Manager PRO (Siemens) Fixed in V7.5
  • Fix · CNA SIMIT V11 (Siemens) Fixed in V11.1

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-52891
  2. 2026-10-03 Alias added: GHSA-gccj-rgh5-5x96

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
See all 2487 →

Sources