Read the docs
TI-2024-00002 Aliases CVE-2024-0002GHSA-ww64-xcqm-5jhf

Improper authentication in Pure Storage FlashArray

Priority MEDIUM 50CWE-287Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-287.

Summary

A condition exists in FlashArray Purity whereby an attacker can employ a privileged account allowing remote access to the array.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00597 48th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Pure StorageFlashArray5.3.17 – 5.3.21; 6.1.8 – 6.1.25; 6.0.7 – 6.0.9; 6.2.0 – 6.2.17; 6.3.0 – 6.3.14; 6.4.0 – 6.4.10; 6.5.0—No fix listedCNA
  • FlashArray VendorPure Storage Affected 5.3.17 – 5.3.21; 6.1.8 – 6.1.25; 6.0.7 – 6.0.9; 6.2.0 – 6.2.17; 6.3.0 – 6.3.14; 6.4.0 – 6.4.10; 6.5.0 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:purestorage:purity\/\/fa:*:*:*:*:*:*:*:*5.3.17 – 5.3.21; 6.0.7 – 6.0.9; 6.1.8 – 6.1.25; 6.2.0 – 6.2.17; 6.3.0 – 6.3.14; 6.4.0 – 6.4.10VulnerablePure Storage
cpe:2.3:a:purestorage:purity\/\/fa:6.5.0:*:*:*:*:*:*:*6.5.0VulnerablePure Storage
  • cpe:2.3:a:purestorage:purity\/\/fa:*:*:*:*:*:*:*:* Versions 5.3.17 – 5.3.21; 6.0.7 – 6.0.9; 6.1.8 – 6.1.25; 6.2.0 – 6.2.17; 6.3.0 – 6.3.14; 6.4.0 – 6.4.10 Vulnerable ·Pure Storage
  • cpe:2.3:a:purestorage:purity\/\/fa:6.5.0:*:*:*:*:*:*:* Versions 6.5.0 Vulnerable ·Pure Storage

Remediation

No fixed version listed by the sources yet.

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    PureStorage FlashArray — purestorage.com/security

    5 records Highest priority Priority MEDIUM 5 MEDIUM

    Other records, highest priority first

    • TI-2024-00001 A condition exists in FlashArray Purity whereby a local account intended for initial…Priority MEDIUM 45
    • TI-2024-00005 Command injection in Pure Storage FlashArrayPriority MEDIUM 42
    • TI-2024-00004 Code injection in Pure Storage FlashArrayPriority MEDIUM 42

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-0002
  2. 2026-10-03 Alias added: GHSA-ww64-xcqm-5jhf

References

  • TI-2024-00001 A condition exists in FlashArray Purity whereby a local account intended for initial… CVSS 3.1CRITICAL 10.0
  • TI-2022-14185 Pure Storage FlashArray products running Purity//FA 6.2.0 - 6.2.3, 6.1.0 - 6.1.12, 6.0.0… CVSS 3.1CRITICAL 9.8
  • TI-2024-00005 Command injection in Pure Storage FlashArray CVSS 3.1CRITICAL 9.1
  • TI-2024-00004 Code injection in Pure Storage FlashArray CVSS 3.1CRITICAL 9.1
  • TI-2024-00003 Improper privilege management in Pure Storage FlashArray CVSS 3.1CRITICAL 9.1
  • TI-2023-18446 Privilege Escalation in VASA CVSS 3.1HIGH 8.8
See all 10 →

Sources