Read the docs
TI-2024-00913 Aliases CVE-2024-0990GHSA-9283-2mpg-73m4

Tenda i6 httpd setAutoPing formSetAutoPing stack-based overflow

Priority HIGH 76CWE-121Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.

Summary

A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.01659 76th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Tendai61.0.0.9(3857)—No fix listedCNA
  • i6 VendorTenda Affected 1.0.0.9(3857) Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:i6_firmware:1.0.0.9\(3857\):*:*:*:*:*:*:*1.0.0.9(3857)VulnerableTenda
cpe:2.3:h:tenda:i6:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:i6_firmware:1.0.0.9\(3857\):*:*:*:*:*:*:* Versions 1.0.0.9(3857) Vulnerable ·Tenda
  • cpe:2.3:h:tenda:i6:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-0990
  2. 2026-10-03 Alias added: GHSA-9283-2mpg-73m4

References

  • TI-2024-00916 Tenda i6 httpd WifiMacFilterGet formWifiMacFilterGet stack-based overflow CVSS 3.1CRITICAL 9.8
  • TI-2026-05285 Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal CVSS 4.0MEDIUM 6.9
  • TI-2024-00914 Tenda i6 httpd setcfm formSetCfm stack-based overflow CVSS 3.1CRITICAL 9.8
  • TI-2024-00915 Tenda i6 httpd wifiSSIDset formwrlSSIDset stack-based overflow CVSS 3.1CRITICAL 9.8
  • TI-2023-26701 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet. CVSS 3.1HIGH 7.5
  • TI-2023-26700 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget. CVSS 3.1HIGH 7.5

Sources