Read the docs
TI-2024-02818 Aliases CVE-2024-3011GHSA-4p7p-xfch-wpqg

Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

Priority HIGH 73CWE-121Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.

Summary

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.01849 79th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaFH12052.0.0.7(775)—No fix listedCNA
  • FH1205 VendorTenda Affected 2.0.0.7(775) Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\(775\):*:*:*:*:*:*:*2.0.0.7(775)VulnerableTenda
cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\(775\):*:*:*:*:*:*:* Versions 2.0.0.7(775) Vulnerable ·Tenda
  • cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-3011
  2. 2026-10-03 Alias added: GHSA-4p7p-xfch-wpqg

References

  • TI-2024-20333 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function. CVSS 3.1CRITICAL 9.8
  • TI-2024-20327 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the mitInterface… CVSS 3.1CRITICAL 9.8
  • TI-2023-20200 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain… CVSS 3.1CRITICAL 9.8
  • TI-2023-20196 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0… CVSS 3.1CRITICAL 9.8
  • TI-2023-20194 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain… CVSS 3.1CRITICAL 9.8
  • TI-2023-20193 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0… CVSS 3.1CRITICAL 9.8
See all 28 →

Sources