Longse model LBH30FE200W cameras, as well as products based on this device, make use of…
Priority LOW 39CWE-1391Published · Updated
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
Longse model LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy. Additionally, every camera with the same firmware version shares the same password.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.002 9th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Longse Technology | LBH30FE200W | all versions | — | No fix listed | CNA |
| Zamel | ZMB-01/C | all versions | — | No fix listed | CNA |
- LBH30FE200W VendorLongse Technology Affected all versions Fixed in — No fix listed CNA
- ZMB-01/C VendorZamel Affected all versions Fixed in — No fix listed CNA
CPE names CISA-ADP · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:h:longse_technology:lbh30fe200w:-:*:*:*:*:*:*:* | not specified by CISA-ADP | — | Longse Technology |
| cpe:2.3:h:zamel:zmb-01:-:*:*:*:*:*:*:* | not specified by CISA-ADP | — | Zamel |
- cpe:2.3:h:longse_technology:lbh30fe200w:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Longse Technology
- cpe:2.3:h:zamel:zmb-01:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Zamel
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-5634
- 2026-10-03 Alias added: GHSA-pcj6-w288-348m
References
More Longse Technology vulnerabilities
- TI-2024-05230 Longse model LBH30FE200W cameras, as well as products based on this device, provide an… CVSS 4.0HIGH 7.5
- TI-2024-05228 Cleartext transmission of sensitive information in Longse Technology NVR3608PGE2W CVSS 4.0MEDIUM 6.0
- TI-2024-05229 Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this… CVSS 4.0MEDIUM 5.3
Sources
- CVE-2024-5634 · CVE Program
- CVE-2024-5634 · NVD
- FIRST EPSS
- GHSA-pcj6-w288-348m · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences