Read the docs
TI-2024-06299 Aliases CVE-2024-6796GHSA-q77r-qvf6-47wr

Vulnerability in Baxter Connex Health Portal

Priority MEDIUM 45CWE-284Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · None
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-284.

Summary

In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00406 35th percentileScored 2026-11-07
Fix Fixed Connex Health Portal (Baxter): 8/30/2024

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
BaxterConnex Health Portalbefore 8/30/20248/30/2024Patch availableCNA
  • Connex Health Portal VendorBaxter Affected before 8/30/2024 Fixed in 8/30/2024 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:baxter:connex_health_portal:*:*:*:*:*:*:*:*before 2024-08-30VulnerableBaxter
  • cpe:2.3:a:baxter:connex_health_portal:*:*:*:*:*:*:*:* Versions before 2024-08-30 Vulnerable ·Baxter

Remediation

  • Fix · CNA Connex Health Portal (Baxter) Fixed in 8/30/2024

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Baxter Connex Health Portal 8/30/2024

    2 records Highest priority Priority MEDIUM 2 MEDIUM

    Other records, highest priority first

    • TI-2024-06298 Vulnerability in Baxter Connex Health PortalPriority MEDIUM 50

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-6796
  2. 2026-10-03 Alias added: GHSA-q77r-qvf6-47wr

References

  • TI-2024-06298 Vulnerability in Baxter Connex Health Portal CVSS 3.1CRITICAL 10.0

Sources