Tenda FH1206 qossetting fromqossetting stack-based overflow
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-121 and the CVSS impact.
Summary
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Tenda | FH1206 | 1.2.0.8(8155) | — | No fix listed | CNA |
- FH1206 VendorTenda Affected 1.2.0.8(8155) Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-7614
- 2026-10-03 Alias added: GHSA-c769-hhrx-qp4m
References
More Tenda Fh1206 Firmware vulnerabilities
- TI-2024-28703 An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows… CVSS 3.1CRITICAL 9.8
- TI-2024-23378 Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability… CVSS 3.1CRITICAL 9.8
- TI-2024-23150 Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow… CVSS 3.1CRITICAL 9.8
- TI-2024-23148 Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow… CVSS 3.1CRITICAL 9.8
- TI-2024-03749 Tenda FH1206 addressNat fromAddressNat buffer overflow CVSS 3.1HIGH 8.8
- TI-2024-23379 Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability… CVSS 3.1HIGH 8.6
Sources
- CVE-2024-7614 · CVE Program
- CVE-2024-7614 · NVD
- FIRST EPSS
- GHSA-c769-hhrx-qp4m · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences