Read the docs
TI-2024-09212 Aliases CVE-2024-9928GHSA-22pf-6rh7-89gj

Missing brute-force protection in Hitachi Energy NSD570 Teleprotection Equipment

Priority LOW 30CWE-307Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
Low · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-307.

Summary

A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second between failed login attempts making it difficult to automate the attacks.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00394 33rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Hitachi EnergyNSD570 Teleprotection Equipment1.0 – 1.20—No fix listedCNA
  • NSD570 Teleprotection Equipment VendorHitachi Energy Affected 1.0 – 1.20 Fixed in — No fix listed CNA

CPE names CISA-ADP · 1

CPEVersionsRoleVendor
cpe:2.3:o:hitachienergy:nsd570_firmware:*:*:*:*:*:*:*:*——Hitachi Energy
  • cpe:2.3:o:hitachienergy:nsd570_firmware:*:*:*:*:*:*:*:* Versions — — ·Hitachi Energy

Remediation

No fixed version listed by the sources yet.

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Hitachi Energy NSD570 Teleprotection Equipment — publisher.hitachienergy.com/preview?DocumentID=8DBD000173&L…

    2 records Highest priority Priority LOW 2 LOW

    Other records, highest priority first

    • TI-2024-09213 A vulnerability exists in NSD570 that allows any authenticated user to access all device…Priority LOW 20

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-9928
  2. 2026-10-03 Alias added: GHSA-22pf-6rh7-89gj

References

  • TI-2019-03985 ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2018-10635 Improper authentication in ICS-CERT ABB eSOMS CVSS 3.0CRITICAL 9.8
  • TI-2024-01871 Heap-based buffer overflow in Hitachi Energy FOXMAN-UN CVSS 3.1CRITICAL 9.8
  • TI-2026-07105 Path traversal in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
  • TI-2019-13270 Path traversal in Relion 670 Series CVSS 3.1CRITICAL 10.0
  • TI-2026-07104 Missing authentication in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
See all 146 →

Sources