Read the docs
TI-2024-09305 Aliases CVE-2024-10025GHSA-m3p3-rf2c-fxw8

Vulnerability in SICK CLV6xx, SICK Lector6xx and SICK RFx6xx

Priority MEDIUM 47CWE-798Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
None · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-798.

Summary

A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00753 55th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SICK AGSICK CLV6xxall versions—No fix listedCNA
SICK AGSICK Lector6xxall versions—No fix listedCNA
SICK AGSICK RFx6xxall versions—No fix listedCNA
  • SICK CLV6xx VendorSICK AG Affected all versions Fixed in — No fix listed CNA
  • SICK Lector6xx VendorSICK AG Affected all versions Fixed in — No fix listed CNA
  • SICK RFx6xx VendorSICK AG Affected all versions Fixed in — No fix listed CNA

CPE names CISA-ADP · 52

CPEVersionsRoleVendor
cpe:2.3:o:sick:lector611_firmware:*:*:*:*:*:*:*:*——SICK AG
cpe:2.3:o:sick:lector610_firmware:*:*:*:*:*:*:*:*——SICK AG
cpe:2.3:o:sick:lector620_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector621_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector622_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector630_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector632_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector640_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector642_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector650_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
  • cpe:2.3:o:sick:lector611_firmware:*:*:*:*:*:*:*:* Versions — — ·SICK AG
  • cpe:2.3:o:sick:lector610_firmware:*:*:*:*:*:*:*:* Versions — — ·SICK AG
  • cpe:2.3:o:sick:lector620_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector621_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector622_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector630_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector632_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector640_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector642_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector650_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
Show 42 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:sick:lector651_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:lector654_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv620_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv621_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv622_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv630_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv631_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv632_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv640_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv642_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv650_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:clv651_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10600_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10601_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10603_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10604_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10605_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10607_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10609_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10610_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10613_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10614_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10618_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu610-10700_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10100_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10101_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10102_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10103_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10104_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10105_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10107_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10108_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10111_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10114_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10118_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10400_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10401_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10500_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10501_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10503_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10504_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
cpe:2.3:o:sick:rfu620-10507_firmware:-:*:*:*:*:*:*:*not specified by CISA-ADP—SICK AG
  • cpe:2.3:o:sick:lector651_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:lector654_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv620_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv621_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv622_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv630_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv631_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv632_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv640_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv642_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv650_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:clv651_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10600_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10601_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10603_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10604_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10605_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10607_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10609_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10610_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10613_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10614_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10618_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu610-10700_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10100_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10101_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10102_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10103_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10104_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10105_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10107_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10108_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10111_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10114_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10118_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10400_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10401_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10500_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10501_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10503_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10504_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG
  • cpe:2.3:o:sick:rfu620-10507_firmware:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·SICK AG

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-10025
  2. 2026-10-03 Alias added: GHSA-m3p3-rf2c-fxw8

References

  • TI-2022-10578 Missing authentication in SICK SIM1004 CVSS 3.1CRITICAL 9.8
  • TI-2022-10577 Missing authentication in SICK SIM1000 FX CVSS 3.1CRITICAL 9.8
  • TI-2022-10576 Missing authentication in SICK SIM2000ST CVSS 3.1CRITICAL 9.8
  • TI-2022-10574 Missing authentication in SICK SIM4000 CVSS 3.1CRITICAL 9.8
  • TI-2026-01971 An attacker may perform unauthenticated read and write operations on sensitive filesystem… CVSS 3.1CRITICAL 9.8
  • TI-2023-09295 Missing authentication in FX0-GENT v3 Firmware CVSS 3.1CRITICAL 9.8
See all 145 →

Sources