SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-94.
Summary
Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| SICK AG | SICK InspectorP61x | before <5.0.0 | <5.0.0 | Patch available | CNA |
| SICK AG | SICK InspectorP62x | before <5.0.0 | <5.0.0 | Patch available | CNA |
| SICK AG | TiM3xx | before <5.10.0 | <5.10.0 | Patch available | CNA |
| SICK AG | TDC-X401GL | all versions and later | — | No fix listed | CNA |
- SICK InspectorP61x VendorSICK AG Affected before <5.0.0 Fixed in <5.0.0 Patch available CNA
- SICK InspectorP62x VendorSICK AG Affected before <5.0.0 Fixed in <5.0.0 Patch available CNA
- TiM3xx VendorSICK AG Affected before <5.10.0 Fixed in <5.10.0 Patch available CNA
- TDC-X401GL VendorSICK AG Affected all versions and later Fixed in — No fix listed CNA
Remediation
- Fix · CNA SICK InspectorP61x (SICK AG) Fixed in <5.0.0
- Fix · CNA SICK InspectorP62x (SICK AG) Fixed in <5.0.0
- Fix · CNA TiM3xx (SICK AG) Fixed in <5.10.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Advisory ·
SICK InspectorP61x, SICK InspectorP62x, TiM3xx — sick.com/.well-known/csaf/white/2024/sca-2024-0006.json
6 records Highest priority Priority MEDIUM 4 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2024-09988 SICK InspectorP61x and SICK InspectorP62x: missing authenticationPriority MEDIUM 42
- TI-2024-09985 SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for pass-the-hash attacksPriority MEDIUM 42
- TI-2024-09984 SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modificationPriority MEDIUM 40
- Advisory ·
SICK InspectorP61x, SICK InspectorP62x, TiM3xx — sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf
6 records Highest priority Priority MEDIUM 4 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2024-09988 SICK InspectorP61x and SICK InspectorP62x: missing authenticationPriority MEDIUM 42
- TI-2024-09985 SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for pass-the-hash attacksPriority MEDIUM 42
- TI-2024-09984 SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modificationPriority MEDIUM 40
Timeline
- 2026-10-02 Threatist record created from CVE-2024-10771
- 2026-10-03 Alias added: GHSA-252q-qph8-r7q3
References
Advisory 2
More SICK AG vulnerabilities
- TI-2022-10578 Missing authentication in SICK SIM1004 CVSS 3.1CRITICAL 9.8
- TI-2022-10577 Missing authentication in SICK SIM1000 FX CVSS 3.1CRITICAL 9.8
- TI-2022-10576 Missing authentication in SICK SIM2000ST CVSS 3.1CRITICAL 9.8
- TI-2022-10574 Missing authentication in SICK SIM4000 CVSS 3.1CRITICAL 9.8
- TI-2026-01971 An attacker may perform unauthenticated read and write operations on sensitive filesystem… CVSS 3.1CRITICAL 9.8
- TI-2023-09295 Missing authentication in FX0-GENT v3 Firmware CVSS 3.1CRITICAL 9.8
Sources
- CVE-2024-10771 · CVE Program
- CVE-2024-10771 · NVD
- FIRST EPSS
- GHSA-252q-qph8-r7q3 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences