IDOR Vulnerability in transformeroptimus/superagi
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · CNA. Fix status from CNA. Impact type from CWE-639.
Summary
An IDOR (Insecure Direct Object Reference) vulnerability exists in transformeroptimus/superagi version v0.0.14. The application fails to properly check authorization for multiple API endpoints, allowing attackers to view, edit, and delete other users' information without proper authorization. Affected endpoints include but are not limited to /get/project/{project_id}, /get/schedule_data/{agent_id}, /delete/{agent_id}, /get/organisation/{organisation_id}, and /get/user/{user_id}.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| TransformerOptimus | transformeroptimus/superagi | up to latest | — | No fix listed | CNA |
- transformeroptimus/superagi VendorTransformerOptimus Affected up to latest Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:superagi:superagi:0.0.14:*:*:*:*:*:*:* | 0.0.14 | Vulnerable | TransformerOptimus |
- cpe:2.3:a:superagi:superagi:0.0.14:*:*:*:*:*:*:* Versions 0.0.14 Vulnerable ·TransformerOptimus
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2024-12048
- 2026-10-03 Alias added: GHSA-m74w-gj86-32q9
References
More TransformerOptimus Superagi vulnerabilities
- TI-2024-08758 Remote Code Execution in transformeroptimus/superagi CVSS 3.0HIGH 8.8
- TI-2024-08736 Path Traversal in transformeroptimus/superagi CVSS 3.0HIGH 8.8
- TI-2024-09513 Information Disclosure in transformeroptimus/superagi CVSS 3.0HIGH 7.5
- TI-2024-08756 Unauthenticated Denial of Service in transformeroptimus/superagi CVSS 3.0HIGH 7.5
- TI-2024-08751 Improper Privilege Management in transformeroptimus/superagi CVSS 3.1HIGH 8.8
- TI-2025-32338 Code Injection in AgentTemplate.eval_agent_config in TransformerOptimus SuperAGI 0.0.14… CVSS 3.1MEDIUM 6.5
Sources
- CVE-2024-12048 · CVE Program
- CVE-2024-12048 · NVD
- FIRST EPSS
- GHSA-m74w-gj86-32q9 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences